Free Pearson Edexcel International A-level Chemistry · Unit 3

Planning measurements and evaluating uncertainty

What you’ll learn

  • Choose apparatus by its range, resolution and purpose.
  • Calculate uncertainties and distinguish precision from accuracy.

Understand the idea

Start a practical plan with the quantity being changed, the response being measured, and the factors that could also affect that response. For a concentration comparison, temperature, total volume and the measurement method should be controlled. A volumetric pipette transfers one fixed volume; a burette measures a variable delivered volume; a measuring cylinder is appropriate when its larger uncertainty is acceptable. Record the reading at eye level and use the supplied apparatus uncertainty rather than assuming that resolution and uncertainty are identical.

A titre is the difference between two readings, so a maximum absolute uncertainty calculation adds the uncertainty of each reading. For products or quotients, add percentage uncertainties when the question asks for the usual maximum uncertainty estimate. Repeats help assess random variation, but cannot remove a common calibration offset. A tightly grouped set can therefore be precise while all its values are inaccurate. State the direction and mechanism of an error before suggesting a specific improvement.

A useful evaluation links the main uncertainty to an action: a larger measurable change reduces its percentage uncertainty, and a more suitable instrument may improve resolution. Neither action automatically removes systematic error. Safety reasoning should likewise connect the stated hazard to exposure: for a corrosive aqueous solution, eye protection and a supervised spill procedure address splashes; they do not justify handling an unidentified substance without the school's risk assessment.

Key formulae

Vdelivered=Vfinal−VinitialV_{\mathrm{delivered}}=V_{\mathrm{final}}-V_{\mathrm{initial}}

uΔV=ufinal+uinitialu_{\Delta V}=u_{\mathrm{final}}+u_{\mathrm{initial}}

u%=uabsolute∣measured value∣×100u_{\%}=\frac{u_{\mathrm{absolute}}}{|\mathrm{measured\ value}|}\times100

A fixed absolute uncertainty matters more for small titres

Conditions. Two readings each bounded by ±0.05 cm³ give maximum difference uncertainty ±0.10 cm³. Curve is 100(0.10/V), for V = 5–50 cm³; other uncertainties are omitted.

Titre / cm³; Maximum percentage uncertainty / %.

At 10 cm³ uncertainty is 1%; at 20 cm³ it is 0.5%. This model compares relative reading uncertainty and does not guarantee that a larger titre removes systematic bias.

Open the interactive lesson to view plotted curves and coordinate tables.

Worked example

A burette changes from 1.701.70 to 20.30 cm320.30\ \mathrm{cm^3}. Each reading has uncertainty ±0.05 cm3\pm0.05\ \mathrm{cm^3}. Find the delivered volume and its maximum percentage uncertainty.

  1. Subtract the readings: V=20.30−1.70=18.60 cm3V=20.30-1.70=18.60\ \mathrm{cm^3}.
  2. Two readings contribute: uV=0.05+0.05=0.10 cm3u_V=0.05+0.05=0.10\ \mathrm{cm^3}.
  3. The percentage uncertainty is 100(0.10/18.60)=0.538%100(0.10/18.60)=0.538\%. State the volume as (18.60±0.10) cm3(18.60\pm0.10)\ \mathrm{cm^3}.

Answer: 18.60 cm318.60\ \mathrm{cm^3}, with maximum percentage uncertainty about 0.54%0.54\%.

Open the interactive lesson to try original questions and recall. Build a revision plan.